    Ideal working pressure

    0.1-0.5Mpa

    Cold water inlet temp.

    4-29 ?

    Hot water inlet temp.

    50-95 ?

    Mixed water outlet temp.

    35-55 oC customized

    Flow rate(1 kg pressure drop)

    26.67 L/min

    Temp accuracy

    ±2?

    Body material

    Nickel plated Brass

    Thread

    G 3/4? Male thread

    Standard

    QB2806-2006

    Net weight

    0.494 KGS

    Gross weight

    0.554 KGS

    1.Technical Data

    DN20M   G3/4”

    a. Working pressure:0.03-1Mpa

    b. Ideal working pressure:0.1-0.5Mpa

    c. Maximum working temperature:=99 C

    d. Flow rate(1 bar pressure drop): 26.67L/Min


    Knob Temperature :

    Position

    Min

    1

    2

    3

    4

    5

    6

    7

    Max

    Temperature(?)

    -

    30

    34

    39

    43

    47

    51

    55

    -

    2. Materials of Construction

    a. Valve body : Brass with Ni-plated

    b. Shutter : PPO

    c. Spring : Stainless steel

    d. Connection : Inlets-Male thread, Outlet-Male thread

    3. Features:

    a. Fail-safe on Hot or Cold Supply Failure

    b. Delivers Stable Mixed Water Temperature

    c. Extended Mix Temperature Range : 35-55 C

    d. Idea for Domestic Water Application

    4. Usage of TMVs

    For wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.

    5. Installation Precaution:

    a.All installations should be carried out by a Licensed Professional.

    b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C

    c. After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2 C.

    d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.

    e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure.

    f. Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation

     


Send your message to this supplier
To:  

Shenyang Beixin Energy Saving Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>